| Availability: | |
|---|---|
HS-910N
Apolomed
Product Description
The HS-910N is an 8-in-1 aesthetic laser platform manufactured by Apolomed, engineered to integrate multiple treatment technologies into a single system. The platform features auto-detect interchangeable handpieces that the system recognizes automatically upon connection, allowing commercial procurement teams to start with a base unit and one handpiece, then add additional handpieces as clinical demand grows. This modular model enables practices to manage initial capital expenditure while preserving the flexibility to expand service offerings without purchasing additional standalone equipment.
The system runs on an ARM-A9 processor with an Android-based operating system, presenting both simple and professional operation modes on a 15.6-inch true color touch screen. The dual-mode interface accommodates practitioners at different experience levels, from entry-level operators to senior clinicians. The cooling system combines TEC water tank cooling with an advanced radiator and an Italy-sourced water pump, supporting extended daily operation schedules.
Certifications include ISO 13485 quality management, SGS RoHS compliance, CE 0197 medical certification, and US FDA 510(k) clearance, providing a documented compliance basis for hospitals, medical centers, dermatology clinics, and plastic surgery facilities.
The IPL handpiece delivers wavelengths from 420-1200 nm with selectable filters including 420/510/560/610/640-1200 nm, 690-950 nm, and SHR mode. The spot size measures 15×50 mm with energy output ranging from 1-30 J/cm² across 10-60 adjustable levels. Applications include skin rejuvenation, skin toning, pigmentation reduction, and hair removal. The system includes pre-set treatment protocols for different indications and skin types.
The Q-switched Nd:YAG handpiece addresses pigmented lesions and tattoo removal. The 1064 nm wavelength targets blue, black, and brown tattoo pigments, while the 532 nm KTP wavelength addresses red, tan, purple, and orange pigments. Pulse width is below 10 ns (single pulse) with repetition rates from 1-10 Hz. Maximum energy reaches 2400 mJ (Φ7) and 4700 mJ (Φ6+Φ7), with spot sizes adjustable from 1-5 mm. An optional Φ7 mm beam expander tip is available for carbon peeling procedures.
The erbium glass fractional handpiece delivers fractional energy for skin resurfacing, surgical scar revision, acne scar treatment, stretch mark improvement, melasma reduction, and deep wrinkle smoothing. The 10×10 pixel mode delivers 25-70 mJ/MTZ, while the 18×18 pixel mode delivers 6-24 mJ/MTZ. Pulse width is fixed at 300 ms. The fractional pattern creates microthermal zones that stimulate collagen remodeling while preserving surrounding tissue for faster recovery.
The long pulse Nd:YAG handpiece provides permanent hair reduction across all skin types, treats leg veins and telangiectasia, and supports wrinkle reduction procedures. Pulse width ranges from 10-40 ms at a 1 Hz repetition rate. Energy density varies by spot size: 10-100 J/cm² at Φ9 mm, 60-240 J/cm² at Φ6 mm, and 150-500 J/cm² at Φ2.2×5 mm. The handpiece incorporates a sapphire cooling treatment lens.
Additional handpieces include the 2940 nm Er:YAG ablative fractional laser, the 1550 nm+1927 nm fractional fiber laser, the diode laser, and the EO Q-switched Nd:YAG laser, each addressing specific clinical indications within the same platform.
Handpiece | 2940nm Er:YAG fractional ablative laser |
|---|---|
Spot size | 10x10mm, Φ6mm, Φ9mm, Φ1-3.5mm |
Energy | 7×7 pixel: 8~52mJ/MTZ |
Repetition rate | 1~6Hz |
Energy | 9x9 pixel: 5~27mJ/MTZ, Beam expander: 400~2600mJ, Zoom lens: 400~2600mJ |
Handpiece | 1540nm Er:Glass fractional laser |
|---|---|
Energy | 10×10 pixel: 25~70mJ/MTZ, 18x18 pixel: 6~24mJ/MTZ |
Pulse width | 300ms |
Handpiece | 1064nm Long Pulse Nd:YAG Laser |
|---|---|
Pulse width | 10-40ms |
Repetition rate | 1Hz |
Energy density | Φ9mm: 10~100J/cm², Φ6mm: 60~240J/cm², Φ2.2*5mm: 150~500J/cm² |
Handpiece | 1064/532nm Q-switch Nd:YAG Laser |
|---|---|
Spot size | 1-5mm |
Pulse width | <10ns (single pulse) |
Repetition rate | 1-10Hz |
Max. Energy | 2400mJ (Φ7) , 4700mJ (Φ6+Φ7) |
Handpiece | IPL / DPL |
|---|---|
Spot size | 15*50mm |
Wavelength | 420-1200nm |
Filter | 420/510/560/610/640-1200nm, 690~950nm, SHR |
Energy | 1~30J/cm² (10~60 level) |
Handpiece | 1550nm+1927nm fiber laser |
|---|---|
Laser output | 1~120mJ/dot |
Handpiece | Diode laser |
|---|---|
Operate interface | 15.6'' True color touch screen |
Cooling | Advanced Air & TEC water tank cooling system |
Power supply | AC 110V or 230V, 50/60Hz |
Dimension | 65*48*115cm (L*W*H) |
Weight | 120Kgs |
Modular 8-in-1 design lowers total equipment investment
Auto-detect handpieces reduce staff training requirements
Scalable procurement: start with one, add more later
CE 0197 and FDA 510(k) cleared for clinical deployment
15.6-inch touch screen with dual operation modes
Combined air and TEC water cooling supports long operation
The HS-910N holds ISO 13485 quality management certification, SGS RoHS compliance, CE 0197 medical certification, and US FDA 510(k) clearance.
Yes. The platform supports a modular procurement model. Buyers can start with the base unit and a single handpiece, then add additional handpieces at a later date based on clinical demand and budget.
Each handpiece contains an identification chip. When connected to the main unit, the system automatically recognizes the handpiece type and loads the corresponding treatment parameters and user interface.
The system employs a combined cooling configuration: TEC (thermoelectric cooler) water tank cooling, an advanced radiator system, and an Italy-sourced water pump. This setup supports continuous operation during busy clinical schedules.
Yes. Apolomed offers OEM and ODM services with an in-house design team and manufacturing experience. Customization options include branding, packaging, and selected parameter configurations based on volume requirements.
Copyright © 2021 Shanghai Apolo Medical Technology Co., Ltd All Right Reserved. Sitemap Support By Leadong